- Other Car Care Equipment[5]
- Auto Ignition System[2]
- Diagnostic Tools[10]
- Other Auto Electrical Systems[1]
- Other Vehicle Equipment[5]
- Wheel Alignment[3]
- Tire Repair Tools[2]
- Car Lifts[6]
- Gas Analyzers[1]
- Multimeters[1]
- Clamp Meters[1]
- Temperature Instruments[1]
- Other Lights & Lighting Products[2]
- LED Flashlights[3]
- Contact Person : Ms. Zheng Aimee
- Company Name : Guangzhou Master Automobile Tech. Co., Ltd.
- Tel : 86-020-28276835
- Fax : 86-020-28276835
- Address : Guangdong,Guangzhou,Room 906, No. 1400 Baiyun Da Dao North, Baiyun District, Guangzhou
- Country/Region : China
2012 Gas Analyzer 4 Gas Analysis For Automobile
Welcome To Our Website!
MST-406EN Automotive Emission Analyzer(4-Gas / Portable)
Main Features and Specifications
1. Measure concentration of HC, CO, CO2, O2 contained in exhaust gases from gasoline engine of vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2 . Designed with LCD screen for easier setting and operation.
2. Automatic calculation and display of A/F (air-fuel-ratio)
and Lambda air ratio λ.
3. Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.
4. Small Size, light weight and most convenient for carry.
5. Designed with inductive clip-on pickup sensor for RPM
measurement.
6. Designed with oil temperature measurement probe.
6. Designed with RS-232C digital serial interface.
7. 200 groups of measurement data storage and review.
8. In compliance with accuracy requirement of ISO 3930
or OIML R99 Class I.
Options and Accessories:
1. Micro printer.
2. Various RPM measurement adaptors.
3. DC12V vehicle power inverter.
Main Technical Specifications
Measuring Range:
HC: 0~9,999 ppm (n-Hexane)
CO: 0~10 %
CO2 : 0~18 % 2
O2 : 0~25 % 2
Measurement Accuracy:
HC: ±12 ppm (abs.) 0~2,000 ppm
±5 % ( rel. ) 0~2,000 ppm (which ever is larger)
±10 % ( rel. ) 2,001~9,999 ppm
CO: ±0.06 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO2 : ±0.5 % (abs.)
±5 % ( rel. ) (which ever is larger)
O2 : ±0.1 % (abs.)
±5 % ( rel. ) (which ever is larger)
Response Time: Less than 10s for T90
(O2, less than 12s)
Warm-up Time: 10 min.
(ambient temperature is not lower than 20°C)
Power Supply: AC220V ±10% 50Hz ±1Hz
Net Weight: 6.0Kg
Outer Dimension:
260mm(W) × 180mm(H) × 450mm(D)
2012 Gas Analyzer 4 Gas Analysis For Automobile